Laser Diode Test
CT8502
LT & RT & HT Die Tester
Features

Integrated Automated Setup
A highly integrated test solution for bare chips
Accurate & Repeatable Testing
Complex and customized test items supported
Robust Maintainable Design
Chuck made of high thermal conductivity and wear resistance material, service life > 2 years
Flexible Production Line Adaptation
Instruments, test plan, pass/fail criteria could be easily configuredFunctions and Advantages

Fully Automated and Intelligent Integrated Solutions

Loading, Unloading and Sorting Module
Loading: The ejector pin mechanism helps the bare die pick up from blue tape.
Test Platform
Support IL (CW/Pulse) Front/back synchronized measurement, spectrum analysis, FFP measurement, etc.
Vision System
Die position correction feedback from camera; high resolution lens for defects inspection; HDMI camera for production monitoring.| Items | Specification | |
| System Parameters | Chip Type | DFB, EML, EML+SOA, Diff EML, etc. |
| Chip Size |
L:150~1000 μm (customizable) W:150~500 μm H:80 μm~150 μm |
|
Test Temperature Zone |
2 | |
| Test Items | Front/back LIV, Spectrum, etc. | |
| Test Parameters | Ith, Se, Iop, Pf, Vf, Kink, Rs, Vr, Ir, Isat, λc, SMSR, etc. | |
| OCR | Auto OCR |
|
| Nozzle | Flat nozzle with waveguide avoided | |
| AOI | Bottom surface(4 faces optional) | |
Loading Container |
1x cassette with 16x 6-inch grip ring |
|
Unloading Container | 1x cassette with 16x 6-inch grip ring |
|
Sorting |
Customer configurable |
|
| Standard Sample Control | Supported | |
| Test Configuration Control | Supports test recipe control, including instruments, algorithms, sequence, test results judgment, etc. | |
| Test Data Management | Support all test data required by users/support MES related requirements | |
| Electrical Indicators(Customizable) | SMU Type | Semight or Third-party SMU |
DC Current |
DC: ±1 A Pulse: ±1.5 A |
|
| I/V Source Resolution | 100 fA/100 nV | |
| I/V Measurement Resolution | 100 fA/100 nV | |
| Voltage Range | ±200 V | |
| Pulse Current |
±1.5 A@1 μs pulse width or ±3 A@250 μs pulse width |
|
| Overshoot under Normal Operation | No EOS | |
| Undershoot under Normal Operation | No EOS | |
Overshoot under Abnormal Operation |
No EOS | |
Undershoot under Abnormal Operation |
No EOS | |
| Optical Indicators | Optical Power Measurement Detector Type | InGaAs/Ge |
| Optical Power Wavelength Range | 800~1700 nm | |
| Optical Power Measurement Range |
10 μW~250 mW: (PD, >25 mW with ND filter) or 100 μW~5 W (Integrating Sphere, >500 mW with ND filter) |
|
| Optical Power Measurement Accuracy | ~6 μW/60 μW/600 μW | |
Optical Spectrum Measurement Range |
1200-1700 nm(determined by OSA model) | |
Optical Spectrum Measurement Accuracy |
0.1 nm(determined by OSA model) | |
| Optical Power Coupling Efficiency | ~10% | |
| Temperature | Temperature Control Method | TEC |
| Temperature Range |
0~95 ℃(target: -45~95 ℃) |
|
| Temperature Area | 2 independent temperature control areas | |
Ramp up Speed |
~30 ℃/min | |
Ramp down Speed |
~30 °C/min | |
| Temperature Accuracy | <±0.5 ℃ | |
| Temperature Stability | <±0.2 ℃ | |
Overall Performance |
Ith Repeatability | <±1% |
| Power Repeatability | <±2% | |
| Wavelength Repeatability | <±0.2 nm | |
| SMSR Repeatability | <3 dB | |
Others |
||
| OCR Success Rate | >99.5% | |
| Cycle Time | <4.5 s (under certain test plan) |