PXIe Source Measure Unit
S2014C
12-channel PXIe SMU
The S2014C is a high precision, compact, cost-effective, 12-channel PXIe Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. It has maximum ±10 V, ± 50mA (DC/pulse) sourcing capability. It supports conventional SCPI commands for easy programming. It supports most standard PXIe chassis and multi-card synchronization. The S2014C can be integrated into production test environment to achieve test efficiency improvement and cost reduction.
Features

High range, High-speed Measurement
±10 V, ±50 mA(DC/pulse)
12-channel Testing System
Based on standard PXIe chassis
Adaptive PFC System
Utilizing Adaptive System
Sensing Mode
Supports 2-wire or 4-wire (remote sensing) connectionFunctions and Advantages

5 Functions In One Card
Voltage source

Test Various Devices

Capture More Measurement Data

Rich Scanning Functions
|
Voltage Precision
|
Measuring Range[1] |
Measuring Resolution |
Accuracy (1 year) ± (% reading + bias)[2] |
Typical Noise (RMS) 0.1 Hz-10Hz |
|
±10V |
1 μV |
0.02%+500μV |
100 μV |
|
| ±6V | 1 μV | 0.02%+300μV | 50 μV | |
|
Temperature Coefficient |
±(0.15 × Precision Indicator)/°C (0℃-18℃,28℃-50℃) |
|||
|
Channel[3] |
CH1-CH12 |
|||
|
Overshoot |
<±0.1% (typical,normal, step range is 10% to 90%,full scale point,resistive load test) |
|||
| Noise(10Hz-20MHz) | <3
mVrms,10V voltage source,50 mA resistive load | |||
[1] Please do not connect the Guard terminal to any output, including shorting to chassis ground or output LO, as it may damage the instrument
[2] Example of accuracy calculation: Testing the accuracy of a 1V output in a 10V range, the allowable tolerance is
[3] All channel outputs are electrically isolated from earth, but each channel output shares a common ground (LO)
|
Current Precision
|
Measuring Range |
Measuring Resolution |
Accuracy (1 year) ± (% reading + bias) |
Typical Noise (RMS) 0.1 Hz-10Hz |
|
±50 mA |
10 nA |
0.05%+12μA |
1 μA |
|
| ±10 mA | 10 nA | 0.05%+2 μA | 100 nA | |
|
±1 mA |
1 nA |
0.05%+200nA |
10 nA |
|
|
±100 μA |
100 pA |
0.05%+20nA |
1 nA |
|
|
±10 μA |
10 pA |
0.05%+2nA |
100 pA |
|
| ±1 μA | 1 pA | 0.05%+300pA | 50 pA | |
|
Temperature Coefficient |
±(0.15 × precision indicator)/°C (0℃-18℃,28℃-50℃) |
|||
|
Channel |
CH1-CH12 |
|||
|
Overshoot |
<±0.1% (typical value,normal, step range is 10% to 90%,full scale point,resistive load test) |
|||
|
Configuration Method |
Configuration Range |
|
NPLC |
0.00005PLC ~ 10PLC |
|
Sampling Rate |
5sps ~ 1.0Msps |