PXIe Source Measure Unit
S2013C
Single-channel PXIe SMU
Features

High Precision
Resolution up to 100 fA/100 nV
High Range and High-speed Measurement
±200 V, ±1A (DC), ±3A (pulse)
Adaptive PFC System
Leverages Adaptive PFC
Building Multi-channel Parallel Test System
Based on standard PXIe chassisFunctions and Advantages

5 Functions In One Card
Voltage source

Can Test Various Equipment

Capture More Measurement Data

Rich Scanning Function

DC I-V Output Capacity

Pulse I-V Output Capacity
|
Voltage Accuracy |
Range | Programming Resolution | Accuracy (1 Year) ± (% reading+ offset)[1] |
Typical Noise(RMS) 0.1 Hz-10Hz |
| ±200 V[2] | 100 μV | 0.03%+10 mV | 400 μV | |
| ±20 V | 10 μV | 0.03%+1 mV | 50 μV | |
| ±6 V | 1 μV | 0.03%+0.4 mV | 12 μV | |
| ±0.6 V | 100 nV | 0.03%+100 μV | 3 μV | |
| Temperature Coefficient | ±(0.15 × accuracy)/°C (0℃-18℃, 28℃-50℃) | |||
| Overshoot | <±0.1% (typical.normal.step is 10% to 90% range, full range, resistive load) | |||
| Noise 10Hz-20MHz |
<5 mVrms, (20V voltage source, 1A resistive load) |
|||

[2] This instrument has a potentially dangerous high voltage (±210 V) output to the HI / Sense HI / Guard terminals. To prevent electric shock, relevant safety precautions must be taken before powering on. Do not connect the Guard terminal to any output, including shorting it to the chassis ground or output LO, as this will damage the instrument
|
Current Accuracy
|
Range |
Resolution |
Accuracy (1 Year) ± (% reading+ offset) |
Typical Noise (RMS) 0.1 Hz-10 Hz |
|
±3 A[3] |
1 μA |
0.03% + 2 mA |
40 μA |
|
|
±1 A |
100 nA |
0.03% + 90 μA |
7 μA |
|
|
±100 mA |
10 nA |
0.03% + 9 μA |
600 nA |
|
|
±10 mA |
1 nA |
0.03% + 900 nA |
60 nA |
|
|
±1 mA |
100 pA |
0.03% + 90 nA |
6 nA |
|
|
±100 μA |
10 pA |
0.03% + 9 nA |
700 pA |
|
|
±10 μA |
1 pA |
0.03% +1 nA |
80 pA |
|
|
±1 μA[4] |
100 fA |
0.03% + 200 pA |
20 pA |
|
|
Temperature Coefficient |
±(0.15 × accuracy)/℃ (0℃-18℃,28℃-50℃) |
|||
|
Overshoot |
<±0.1% (typical. normal mode. step is 10% to 90% range, full range, resistive load) |
|||
[3] 3A range is available only for pulse mode, accuracy specifications for 3A range are typical
[4] Low Current Measurements, Triaxial Cable is recommended to connect: HI connect to core cable, Guard connects to inner shield, outer shield connects to protective ground, LO connect to core cable, inner shield not connect, and outer shield connect to protective ground. Triaxial Cable rated insulation voltage is not less than 250V
| Minimum Programmable Pulse Width | 100 μs | |||
| Pulse Width Programming Resolution | 1 μs | |||
| Pulse Width Programming Accuracy | ±10 μs | |||
| Pulse Width Jitter | 2 μs | |||
| Pulse Width Definition | The time from 10% leading to 90% trailing edge as follows | |||

| Maximums | Maximum Pulse Width | Maximum Duty Cycle | |
| 0.1 A/200 V | DC, no limit | 100% | |
| 1 A/20 V | DC, no limit | 100% | |
| 3 A/66.6 V | 1 ms | 5% | |
| 3 A/160 V | 400 μs | 2% | |
| Source | Maximum Output | Typical Rise Time[5] | Typical Settling Time[6] | Test load |
|
|
160 V | 800 μs | 1.2 ms | No load |
| 5 V | 50 μs | 100 μs | No load | |
|
|
3A~1 mA | 90 μs | 250 μs | Full load[7] |
| 100μA ~10 μA | 150 μs | 400 μs | Full load[7] | |
| 1 μA | 800 μs | 1.2 ms | Full load[7] |
[5] Leading edge, the time from 10% leading to 90% leading
[6] The time required from pulse out 0 to reach within 1% of final value
[7] Test condition: Normal, resistive load 6V maximum output
| Setting | Range | |||
| NPLC | 0.00005 PLC ~ 10 PLC | |||
| Sampling Rate | 5 sps ~ 1 Msps | |||
|
Source |
Range |
Output Settling Time[8] |
Condition |
||
|
Fast[9] |
Normal |
Slow |
|||
|
Voltage |
200 V |
<600 μs |
<2 ms |
<2 ms |
Time required to reach within 0.1 % of final value at open load condition. |
|
20 V |
<80 μs |
<150 μs |
<800 μs |
||
|
6 V |
<60 μs |
<100 μs |
<300 μs |
||
|
0.6 V |
<60 μs |
<60 μs |
<60 μs |
||
|
Current |
3 A~1 mA |
<100 μs |
<180 μs |
<0.8 ms |
Time required to reach within 0.1% (0.3% for 3A range) of final value at short condition. |
|
100μA~10 μA |
<150 μs |
<250 μs |
<0.8 ms |
||
|
1 μA |
<1 ms |
<1 ms |
<1 ms |
||
[8] Output transition speed:Fast, Normal, Slow. Users can adjust the APFC parameters based on the load characteristics to obtain precision, and fast output characteristics
[9] Slow mode is recommended for overshoot sensitive equipment, Fast mode may have overshoot on output in some condition