Pulse
S3026P
Precision PSMU
S3026P is a single channel, pulse current Source/ Measure Unit(SMU) aimed for testing LiDAR. It supports high-precision pulse current output and synchronous measurement of pulse current with DUT voltage drop.
Features

Pulse Width
Minimum 1 μs, maximum 500 μs
High-speed Measurement
ADC up to 100 MSa/s
High Range
Supports pulse current output up to ±1.5A
Stronger Load Adaptability
Test loads with different characteristics to ensure that the waveform does not experience overshoot or other distortions
High Speed Synchronization
Multi-channel and multi-mode collaborative measurement
Real Time Reading of DUT Voltage Drop for Pulse Current
No additional equipment required, precise monitoring of current testing conditions, real-time reading back of test resultsFunctions and Advantages

Sweep Mode
Supports single linear, double linear, constant, logarithmic, and list sweeps, with a maximum of 65535 points per sweep. It also supports infinite pulse and DC output modes. List sweep is flexibly configurable as needed.|
Parameter |
Specification |
|||
|
Current Accuracy |
Range |
Resolution |
Accuracy(1 Year) ±(%reading + offset)[1] |
Typical Noise[1](RMS) 1 Hz - 10 MHz |
|
±150mA[2] |
20μA |
0.1%+0.2mA |
0.2mA |
|
|
±750mA |
20μA |
0.1%+0.3mA |
0.3mA |
|
|
±1.5A |
40μA |
0.1%+0.8mA |
0.4mA |
|
|
Maximum Load Drop Voltage |
10V |
|||
|
Pulse Width Resolution |
80ns |
|||
|
Maximum Pulse Width Ton-max |
500μs |
|||
|
Minimum Pulse Width Ton-min |
1μs[4][5][6] |
|||
|
Minimum Pulse Off-Time Toff-min |
100μs |
|||
|
Pulse Width Accuracy |
100ns[4] |
|||
|
Pulse Width Jitter |
500ns(typ.) |
|||
|
Rising Time(10%-90%) |
<400ns[4][5][6] |
|||
|
Pulse Overshoot |
<3%[4][5][6] |
|||
|
Current Regulation |
Line Regulation |
0.05% of full scale |
||
|
Load Regulation |
±100μA |
|||
|
Duty Cycle Limit[7] |
D≤50%; and satisfies: D<3/[(Vlimit−Vload)×|Iset|−|Ibias|] |
|||
|
Maximum Pulse Points Per Sweep |
65535 |
|||
[1] Test Conditions: Pulse width is set to the maximum pulse width (500 μs). Current is measured using a high-precision ammeter with a measurement speed of 0.02 NPLC.
[2] Internal switching; no user configuration required.
[3] With a 10 Ω resistive load, voltage noise across the load is measured, and current noise is calculated via I = V / R.
[4] Bias current > 1 mA. Pulse width is measured from 10% of rising edge to 90% of falling edge.
[5] 0.5 Ω resistive load.
[6] Total inductance of output leads and DUT < 200 nH (at 100 kHz).
[7] Iset:Set current; Ibias:Bias current; D: Duty cycle;Vlimit Source voltage setting, adjustable range 5 V to 40 V;Vload: Maximum load voltage drop.
Note: In current mode, the unit automatically monitors the loop condition. If an external open circuit is detected, the unit disables output and reports an error.
Example: Using a 1 Ω resistive load, with the sweep current range from 0 A to 1.5 A, the Vload is 1.5 V. With Ibias set to 0 A, D < 3 / [(Vlimit - 1.5 V) × (1.5 A - 0)].
When Vlimit is set to 20 V: D < 10.8%.
When Vlimit is set to 10 V: D < 23.5%.
|
Parameter |
Specification |
|||
|
Pulse Voltage Measurement |
Range |
Resolution |
Accuracy ±(%reading+offset) |
|
|
6V |
1mV |
0.1%+22mV |
||
|
10V |
10mV |
0.1%+24mV |
||
|
Pulse Current Measurement |
Range |
Resolution |
Accuracy ±(%reading+offset) |
|
|
150mA |
100μA |
0.1%+1mA |
||
|
750mA |
100μA |
0.1%+3mA |
||
|
1.5A |
1000μA |
0.1%+7mA |
||
|
Sense Terminal Limits |
Maximum voltage between HI and SENSE HI: ±1 V |
|||